SCBA Cylinder Time Calculator


How to Calculater Work

The SCBA (Self-Contained Breathing Apparatus) calculator helps users estimate how long an air cylinder will last during use in hazardous or confined spaces.

🔸 Formula Used:

Total Air Volume (litres) = Cylinder Volume × Pressure
👉 e.g., 6L × 200 bar = 1200 litres

Theoretical Duration (minutes) = Total Air ÷ Breathing Rate
👉 e.g., 1200 ÷ 40 L/min = 30 minutes

Usable Working Time = Theoretical Duration ÷ 3
👉 10 minutes (This follows the Rule of Thirds:
→ ⅓ for entry
→ ⅓ for exit
→ ⅓ reserve/emergency)

How to Use This SCBA Calculator:

  1. Enter the cylinder volume (in litres) – e.g., 6 L.
  2. Enter the pressure (in bar) – e.g., 200 bar.
  3. Enter your air consumption rate (in litres per minute) – usually around 40 L/min.
  4. Click “Calculate” to instantly get:
    • Total air volume in litres
    • Theoretical working time
    • Usable safe time (based on the Rule of Thirds)

Who Should Use This Calculator:

  • Safety officers and HSE professionals
  • Firefighters and emergency responders
  • Confined space workers
  • Training institutes and safety course students
  • Anyone using SCBA (Self-Contained Breathing Apparatus) in hazardous environments

Why You Should Use It:

  • 🛑 Safety First: Prevent running out of air in confined or hazardous spaces
  • ⏱️ Plan Your Time: Know exactly how long you can safely stay in an environment
  • 🔁 Rule of Thirds: Calculates based on standard safety practice — one-third air for entry, one-third for exit, one-third reserved for emergencies

SCBA calculator,
SCBA time calculation,
SCBA duration calculator,
SCBA air cylinder calculator,
SCBA working time calculator,
SCBA safety calculation tool,
confined space SCBA calculator,
calculate SCBA duration online,
SCBA rule of thirds calculator,
SCBA air supply time estimation

1 thought on “SCBA Calculator: Estimate Air Supply Duration for Confined Space Work”

Leave a Comment